However, you can??™t use this alias to change any of the settings.
UPS Provides complete statistics about the Uninterruptible Power Supply (UPS) attached to
the target system. The statistics you receive depend, in part, on the capabilities of the UPS. Newer
UPSs tend to provide more information than older setups. In some cases, you can even detect the
operating temperature of the UPS. The UPS must rely on the UPS service in Windows for this
feature to work. You can??™t change any of the UPS feature settings using this alias.
UserAccount Manages user account information. You can add, delete, or modify user entries
as needed. The modifications include the ability to rename the user account, disable the account,
and set account password requirements. For example, if you want to set the user??™s full name,
you would type WMIC UserAccount Where Name="UserName" SET FullName="FullName" and
press Enter.
Voltage Provides information about any voltage sensors installed on the system. Unfortunately,
this feature doesn??™t work at all on older systems and may not work on newer systems
either. When this alias does work, you obtain a considerable amount of information about the
sensor??”everything you could ever want except the power supply voltages.